19'' 6U Chassis page 45/71
Procedure
Fall Back 4
In the event of incorrect completion of the Generic slot MS Module Code Upgrade
Remote Loading Phase, or a problem with the new code, the uploaded package can be
removed from the RAM by the following procedure:
• Set the object:
• mgnt2LoadDelete
Location:
…
\microsens\mgnt2\mgnt2SoftwareManagement\mgnt2LoadMSTable\mgnt2Load
MSEntry
This action deletes the associated file from the RAM.
End procedure
Procedure
Fall Back 5
In the event of incorrect completion of the Generic slot MS Module Code Upgrade
Transfer Phase, or a problem with the new code, the transferred file must be
overwritten with a valid Software or Gateware.
Restart the procedure.
End procedure
Procedure
Fall Back 6
In the event of incorrect completion of the Generic slot MS Module Code Upgrade
Activation Phase, or a problem with the new code, the new code must be taken out of
service.
To do this a reset is required to revert back to the former code:
In the case of a Software change, a Cold or Warm Reset will achieve this, selecting the
bank containing the previous version of Software.
In the case of a Gateware change, a Cold reset is required selecting the bank containing
the previous version of Gateware.
All Reset procedures are described in the Software Management section of the generic
slot MS SNMP User Manual.
End procedure
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com