19'' 6U Chassis page 41/71
Location:
...\microsens\mgnt2\mgnt2SoftwareManagement\mgnt2LoadMSTable\
mgnt2LoadMSEntry
Bank 1 o r 2 for Software. Bank 1, 2, 3 or 4 for Gateware. Selection of the type of
code is automatic based on the file extension.
The new code becomes active following a module reset. The type of reset can be
determined at this stage:
• Select the reset method using the object:
mgnt2LoadResetMethod
Location:
..\microsens\mgnt2\mgnt2SoftwareManagement\mgnt2LoadMSTable\mgnt2Load
MSEntry
Possible values of this object are:
Manual – 0
The User will manually switch the new code into service following the instructions
in the Activation Phase.
Immediate – 1
With this option the Module will Reset automatically on completion of the
transfer. In the case of a Software transfer the type of Reset is User defined (cold
or warm), in the case of a Gateware transfer the Reset will be a cold Reset.
Scheduled – 2
This option is reserved for future use.
• Select reset mode.
In the case of a Software transfer and when the Reset method is Immediate or
Scheduled the type of Reset is defined using the object:
• mgnt2LoadResetMode
Location:
..\microsens\mgnt2\mgnt2SoftwareManagement\mgnt2LoadMSTable\mgnt2Load
MSEntry
Possible values of this object are:
Cold Reset – 0 (traffic may affecting)
Warm Reset – 1 (traffic not affected)
In the case of a Gateware transfer it is mandatory to select the Cold reset option.
In the case of a Software transfer, it is recommended to select the Warm reset
option.
• Start the transfer by setting the object:
mgnt2LoadTransfer
Location:
..\microsens\mgnt2\mgnt2SoftwareManagement\mgnt2LoadMSTable\mgnt2Load
MSEntry