19'' 6U Chassis
Overview
6U Chassis is a part of MICROSENS 10G Transport Platform, a high performance and
flexible carrier-class transmission system. The 10G Transport Platform enables increasing
transport capacities in CWDM, DWDM and SDH networks. The use of wide range TDM
modules permits to reduce the number of necessary wavelengths and to decrease the
overall cost of the application. Ethernet over SDH modules enable using existing
SONET/SDH infrastructure for IP transmission.
The general features of the system:
19“ 2U Chassis with 5 module slots and management card
Max. 5x single size modules i.e. 2x double size + 1x single size module
Hot swappable modules & power supplies
Redundant power supplies with -48 VDC input (opt. 230 VAC)
Exchangeable air- and filter module
Wide range of functional xWDM and TDM modules available
The functional modules of 10G Transport Platform include:
TDM 8x GBE or 8x GFC to 10G/OC-192/STM-64
TDM 5x GBE or 5x 2GFC to OC-192/STM-64
TDM 4x OC-48/STM-16 to 10G/OC-192/STM-64
TDM 2x GBE and 2x GFC to OC-48/STM-16
10G transponder with 3R, XFP and fixed Laser Versions
10G protocol converter 10G LAN to 10G WAN (OC-192/STM-64)
DWDM MUX/DeMUX, OADMs, EDFAs
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
MICROSENS
Zobrazit stránku 0
1 2 3 4 5 6 ... 70 71

Shrnutí obsahu

Strany 1 - MICROSENS

19'' 6U ChassisOverview6U Chassis is a part of MICROSENS 10G Transport Platform, a high performance andflexible carrier-class transmission s

Strany 2 - Features

19'' 6U Chassis page 10/71Figure 9: MS430502M chassis Front view.Installing the MS430502M chassisRack mount InstallationSecurely attach one

Strany 3

19'' 6U Chassis page 11/71Figure 10: Ground screw location.• Connect the cable(s) provided to a correctly protected -48V supply.Fuse Rating:

Strany 4 - MGNT Management Unit

19'' 6U Chassis page 12/71Preventive MaintenanceDust Filter replacement ProcedureThe dust filter should be visually examined on a six month

Strany 5

19'' 6U Chassis page 13/71MGNT boards are shipped with the Agent software loaded. Note the versionrequired on your site in the case where th

Strany 6

19'' 6U Chassis page 14/71The rescue CLI allows the user to perform all the upgrade procedure described in theCLI documentation.Use the foll

Strany 7 - Mechanical Description

19'' 6U Chassis page 15/71FAN Fan Unit The following alarms indicate a problem with the Fan Unit:• mgnt2AlmFansFailure This bit indicat

Strany 8

19'' 6U Chassis page 16/71Module maintenanceModule Replacement ProcedureUse the following procedure to replace a MS module:This procedure is

Strany 9 - Installation Manual

19'' 6U Chassis page 17/71ms43062XMRinvSfpTableLocation: ...\microsens\modulems43062XM\ms43062XMri\• Use you SNMP browser to check if there

Strany 10

19'' 6U Chassis page 18/71SFP Replacement Procedure on MS43062XMEach Client port has its own LED located on the front panel of the MS module

Strany 11

19'' 6U Chassis page 19/71• Clean Fibre Optic connectors on fibre optic cable• Re-connect Fibre• Verify correct operation of the SFPEnd proc

Strany 12 - Corrective Maintenance

19'' 6U Chassis page 2/71IntroductionThe MS430502M chassis which is capable of hosting up to ten aggregation andtransport MS modules. The MS

Strany 13

19'' 6U Chassis page 20/71 ...\microsens\moduleMS430601M\ms430601mcontrolsWrite\ms430601mCtrlLine\ ms430601mCtrllineSfpOnO

Strany 14

19'' 6U Chassis page 21/71• Check the inventory to verify type of XFP currently installed. Consult theobject:ms43062XMRinvXfpLocation: ...\m

Strany 15

19'' 6U Chassis page 22/71SNMP User ManualInitial Set-Up and ConfigurationConfigurationConnecting to the managerThe MS430502M chassis contai

Strany 16

19'' 6U Chassis page 23/71• Automatic with DIP switchesThe MS430502M chassis MGNT Management Board is equipped with 8 DIPswitches that may

Strany 17

19'' 6U Chassis page 24/71To the value xxx.yyy.zzz.1, where xxx.yyy.zzz defines the MS430502M chassis IPAddress map.2. Configure the DIP swi

Strany 18

19'' 6U Chassis page 25/71performed using a ping function. The estimated time to detect a dead gateway is lessthan 30 seconds.The table• mgn

Strany 19

19'' 6U Chassis page 26/71The object mgnt2GigmRwCommunity is not readable. The returned value is always“*******”.• mgnt2GigmTrapCommunity, d

Strany 20

19'' 6U Chassis page 27/71Version Number: 06Release date (yymmddww):06101241mgnt2RinvLinuxAgent identification.Example Response:Linux Part N

Strany 21

19'' 6U Chassis page 28/71mgnt2AlmMsSlot6AbsentMS present in Chassis slot 6: This OID indicates the presence of a MSmodulein Slot 6 of the C

Strany 22 - SNMP User Manual

19'' 6U Chassis page 29/71file must be cleared to insure correct logfunctionfunctionmgnt2AlmLog80FullLog File Full Warning :This OID indicat

Strany 23

19'' 6U Chassis page 3/71Figure 1: Management cards and generic slots organisation.The ten additional generic slots available in the MS43050

Strany 24

19'' 6U Chassis page 30/71Name Description ValueAPI Information CodesDEF_API_OK Default Value 0DEF_API_COLD_RESET_MODULE Cold Reset request

Strany 25

19'' 6U Chassis page 31/71Software ManagementMIB location:...\microsens\mgnt2\mgnt2SoftwareManagement\In all the following procedures, the u

Strany 26

19'' 6U Chassis page 32/71When renaming the package ensure that the new name is compliant with theUnix standard and no more than 24 characte

Strany 27

19'' 6U Chassis page 33/71And which one is currently being extracted by the variable:mgnt2ExtractedPack• Check the presence of the required

Strany 28

19'' 6U Chassis page 34/71• Progress indicator:The value of: mgnt2PackageExtractionInProgressCan be consulted to monitor the progress of the

Strany 29

19'' 6U Chassis page 35/71Procedure1. Remote Loading PhaseThe object of this phase is to load the software package into the RAM of theMS4305

Strany 30

19'' 6U Chassis page 36/71• Check that your package is loaded correctly by consulting the table:mgnt2DwlUploadingTableLocation:...\microsens

Strany 31

19'' 6U Chassis page 37/71In the event of an incorrect completion of this phase see FallBack 2 for reverse procedure. (Fall Back Procedures)

Strany 32

19'' 6U Chassis page 38/71Associated with the package to be erased.If the package that you intend to erase from the FLASH is in use, i.e.:mg

Strany 33

19'' 6U Chassis page 39/71T:\home\> tftp -i 192.168.16.123 PUT xxx.ext /tftpboot/yyy.extWhere: T:\home – is the location of the code on y

Strany 34

19'' 6U Chassis page 4/71Figure 2: MS430502M chassis General Block diagram.MGNT Management UnitThe block diagram of the MGNT unit is given i

Strany 35

19'' 6U Chassis page 40/71msXXXXXXXDwlgwBanksUsed• Gateware :msXXXXXXXDwlGwBank1NotemptymsXXXXXXXDwlGwBank2NotemptymsXXXXXXXDwlGwBank3Notemp

Strany 36

19'' 6U Chassis page 41/71 Location: ...\microsens\mgnt2\mgnt2SoftwareManagement\mgnt2LoadMSTable\mgnt2LoadMSEntryBank 1 o r 2 for

Strany 37

19'' 6U Chassis page 42/71Normal management operations may be carried out during the transfer, howeverthe response time may be a little slow

Strany 38

19'' 6U Chassis page 43/71msxxxxxxxRinvGwPlatformLocation: …\microsens\moduleMsxxxxxxx\msxxxxxxxriVerify that the versions are correct.In th

Strany 39

19'' 6U Chassis page 44/71If the package that you intend to erase from the FLASH is in use, i.e.:mgnt2ExtractedPack = "two", this

Strany 40

19'' 6U Chassis page 45/71ProcedureFall Back 4In the event of incorrect completion of the Generic slot MS Module Code UpgradeRemote Loading

Strany 41

19'' 6U Chassis page 46/71ResetsThe following describes the various methods of resetting the MGNT board.Under no circumstances should a Rese

Strany 42

19'' 6U Chassis page 47/71Figure 14: MGNT Management board reset button.Visual indications:The colour sequence of the front panel LEDs are:H

Strany 43

19'' 6U Chassis page 48/71• Set the object: mgnt2CtrlChassisShutDownLocation: ...\microsens \mgnt2\mgnt2Hardware \mgnt2controls\• Using a co

Strany 44

19'' 6U Chassis page 49/71• Power Up:Connect the -48V supply(s) on the front panel.• Visual indications:The colour sequence of the front pan

Strany 45

19'' 6U Chassis page 5/71The main characteristics of the MGNT management unit are:• Processor: 32 bit, 177 MHz• RAM memory: 64 Mbytes• Flash

Strany 46

19'' 6U Chassis page 50/71Front view The object:• mgnt2GigmSelectedBoardLocation:…\microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagem

Strany 47 - End procedure

19'' 6U Chassis page 51/71Upload a configurationA user may upload the configuration of a MSxxxxxxx module to a PC via the MGNTmanagement boa

Strany 48

19'' 6U Chassis page 52/71• Use your SNMP browser to check the backup file presence in the FLASHmemory of the MGNT management board using th

Strany 49

19'' 6U Chassis page 53/71• Open a Command Line Interface window from your operating system and goto the directory where you want to store t

Strany 50

19'' 6U Chassis page 54/71Location:...\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfUploadConfigFilesTable• Open a Command Line Interface w

Strany 51

19'' 6U Chassis page 55/71Location:...\microsens\mgnt2\mgnt2ConfigManagement\mgnt2CnfUploadConfigFilesTableThis validates the transfer of th

Strany 52

19'' 6U Chassis page 56/71The MGNT management board will check the compatibility between the backupconfiguration file and the target MSxxxxx

Strany 53

19'' 6U Chassis page 57/71Figure 15: Connecting two MS430502M chassis with 2nd ethernet portIf using a table top mount you can stack up to 5

Strany 54

19'' 6U Chassis page 58/71Connect the new MS430502M chassis to the last one installed using an Ethernetcable (straight or crossover)It is ne

Strany 55

19'' 6U Chassis page 59/71If the incoming line is transporting the management information on DCC, it is highlyrecommended to disable the DCC

Strany 56

19'' 6U Chassis page 6/71If a failure occurs on one of the two main power converters, it is detected by a failurecircuitry and the protectio

Strany 57

19'' 6U Chassis page 60/71AppendixesLaser ClassLaser Class Risks General Requirements1Considered safe to eye and Skin underall reasonably fo

Strany 58

19'' 6U Chassis page 61/71MGNT2 MIB descriptionOID Name Access Description1.3.6.1.4.1.20044.7.1 mgnt2SNMPAgentData1.3.6.1.4.1.20044.7.1.1 mg

Strany 59

19'' 6U Chassis page 62/711.3.6.1.4.1.20044.7.1.2.1.1 mgnt2GigmBoardEntry n/a Row Definition for theMSs table1.3.6.1.4.1.20044.7.1.2.1.1.1

Strany 60 - Appendixes

19'' 6U Chassis page 63/71community:This OIDdefines the communityfor the SNMP Getfunction1.3.6.1.4.1.20044.7.1.8.2 mgnt2GigmRwCommunity r/

Strany 61 - MGNT2 MIB description

19'' 6U Chassis page 64/71A is in fail condition onthe Management board1.3.6.1.4.1.20044.7.2.1.0.16 mgnt2AlmMgntDefFuseB rMgnt Fuse B Fail :

Strany 62

19'' 6U Chassis page 65/71unit or no rotation setsthe OID1.3.6.1.4.1.20044.7.2.1.24 mgnt2AlmfanPwrMgmnt1.3.6.1.4.1.20044.7.2.1.24.13 mgnt2Al

Strany 63

19'' 6U Chassis page 66/71Management Module:This oid triggers a 'warm'reset of the Chassis . Thistype of reset is not trafficaffec

Strany 64

19'' 6U Chassis page 67/711.3.6.1.4.1.20044.7.4.1.1.4 mgnt2FileUpload r/wAgent File Upload: ThisOID validates the uploadofthe SNMP agent fro

Strany 65

19'' 6U Chassis page 68/71the repository1.3.6.1.4.1.20044.7.4.4.1 mgnt2LoadMSEntry n/aRow definition for theLOAD article table1.3.6.1.4.1.20

Strany 66

19'' 6U Chassis page 69/711.3.6.1.4.1.20044.7.4.6.1.2 mgnt2DwlMScraftPkgFileName rPackage File name inFLASH: This OID gives thenameof the MS

Strany 67

19'' 6U Chassis page 7/71Interface SpecificationsPower SupplyDC input power range: nominal: -36Vmaximum: -72VMS430502M chassis equipped with

Strany 68

19'' 6U Chassis page 70/711.3.6.1.4.1.20044.7.5.2.1 mgnt2CnfManageConfigFilesEntry n/aRow definition for thepackage uploading table1.3.6.1.

Strany 69

19'' 6U Chassis page 71/71the Mgnt2 managementmodule1.3.6.1.4.1.20044.7.3.1 mgnt2TrapApi n/aApi error trap with itsnumber1.3.6.1.4.1.20044.7

Strany 70

19'' 6U Chassis page 8/71Figure 7: MS430502M chassis mechanical dimension (ETSI flange).Figure 8: MS430502M chassis mechanical dimension (19

Strany 71 - Order Information

19'' 6U Chassis page 9/71Installation ManualSite Preparation.Before installation ensure that your site meets the following requirements:Moun