When serial port stops data transmission for a defined period of time
(Idle Timeout), the connection will be closed and the port will be freed
and try to connect with other hosts. 0 indicate disable this function.
Factory default value is 0. If Multilink is configured, only the first host
connection is effective for this setting.
The serial device will send TCP alive-check package in each defined
time interval (Alive Check) to remote host to check the TCP
connection. If the TCP connection is not alive, the connection will be
closed and the port will be freed. 0 indicate disable this function.
Factory default is 0.
The number of Max connection can support simultaneous connections
are 5, default values is 1.
*Not allowed to mapping Virtual COM from web
Service Mode – TCP Server Mode
In TCP Server Mode, Device Server is configured with a unique Port combination on
a TCP/IP network. In this case, device waits passively to be contacted by the
device. After the device establishes a connection with the serial device, it can then
proceed with data transmission. TCP Server mode also supports up to 5
simultaneous connections, so that multiple device can receive data from the same
serial device at the same time.